Operators Handbook and Service Manual TEKK KS-960 (KS-900N) Crystal Controlled Digital Data Radio This Manual is intended f
2) Adjust the signal generator to receive frequency and set the output level to 1mV. Adjust the modulation to 1000 Hz(*) with a deviat
12) While observing the wave form on the oscilloscope, change the output voltage of the power supply between 8 volts and 12 volts and note that there
6) Connect the spectrum analyzer between the radio and the 50 ohm power meter. Set the Spectrum analyzer to display a frequency spectrum from zero t
Introduction The KS-960 Series is available in a Low and High Band configuration. The suffix L and H indicate Low and High respectively. The Low
Sensitivity <0.35 uV for 12 dB SINAD Selectivity 70dB Spurious Rejection 60dB Frequency Stability +/- 5ppm Audio Response Flat Audio Distortion <
The KS-960 is a Half-Duplex UHF Transceiver with crystals controlling the Transmit and Receives Frequencies. Half-Duplex indicates that th
In many Modems, the Data Out Signal used to Modulate the KS-960 is a fixed level. To allow for proper modulation of the KS-960 a level or deviation c
A Microampmeter may be connected directly to Pin 8 to indicate the relative strength of the received signal. The circuit has a dynamic range of about
The input, Pin 16, of IC1 is connected directly to the internal mixer. Pins 1 and 2 are the frequency controlling pins of the internal oscillator.
All of the receiver stages are supplied with a constant +B voltage from the regulator transistor Q10. This voltage can be checked at
The base voltage of Q8 is held constant by the Zener Diode D9. The emitter voltage of Q8 is then a constant value around 5 volts. This 5