Analytical Modules, continued
Step Procedure
9. Reinstall the Flat Washer, Lock Washer, and Button Head Hex
Screw. Do not over tighten the screw as this can damage the
Board.
10. Reconnect wiring to the board. Wiring MUST be connected to
the same cells as before. Verify all termination points.
Note: The length of the wiring is such that color coded wires can
connect only to their specified bead. Also note that there are
two wires of each color. Technically, for a specific cell it does
not matter which wire is connected to which lead as long as the
color is correct. However, the wires should be connected as
shown in figure 4-11.
Figure 4-11: Wiring Connections to Thermistor Boards